Appendix G – Bar Code Details
Class Series 2 Programmer’s Manual 241
<STX>L
D11<CR>
1WM00000005000501139987520<CR>
E
Barcode W1M
Note that the human readable shows the format control code, sorting code and the
generated Reed Solomon error correction parity values.
Example 2:
The following example prints a Customer Bar Code 2 using a DPID of “32211324” and
customer information “A124B”:
<STX>L
D11<CR>
1Wm00000005001505932211324A124B<CR>
E
Barcode W1m
W1n / W1N: Industrial 2 of 5
Industrial 2 of 5 is a discrete, self-checking, continuous numeric bar code. All of the
information is contained in the bars, either wide or narrow, typically in a 3:1 ratio. The
space is equal to the width of the narrow bar.
Valid Characters: 0-9
Variable length, minimum one digit
Human Readable: W1N; and, Non-Human Readable: W1n
Example:
The following example prints an Industrial 2 of 5 with
a human readable field:
<STX>L
D11
1W1N8305001000100123456
E