Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 41
STX KaW Write Data to RFID Tag
(Direct Mode – Generic Read/Write Interface)
This command instructs the RFID device to write data to the tag. It is expected that the
tag transponder will be within the read / write distance of the RFID programming device;
otherwise, a warning will occur and a warning message (Read / Write Fail) will be
displayed.
Syntax:
<
STX>KaWAaaabbbcdee…
e
<
CR
>
Where:
Aaaa
-
Optional – for data in the ASCII format, followed by
the byte count (000-999).
bbb
-
HF – Starting block number (000 maximum block
number, which is dependent upon the
transponder manufacturer).
UHF – Should be 000.
c
-
Command 1. Reserved for Future (should be 0)
d
-
Command 2. Reserved for Future (should be 0)
ee…e
-
Data to be encoded on RFID tag (HF – the last used
block will be null-padded, if necessary).
UHF ASCII formats must be 8 or 12 characters; and,
UHF Hexadecimal formats must be 16 or 24
character pairs.
Sample:
<STX>KaW0000054455354[CR]
The sample above writes the data “TEST” at block zero.
STX Kb Backfeed Time Delay
This command controls the time a printed label is allowed to remain “presented” before
being retracted to the start of print position.
Syntax:
<
STX>Kbnnn
<
CR
>
Where:
nnn
-
Seconds/10
Vedere la pagina 54