Appendix U – Display Icon Key and Control Panel Button Sequence Functions
312 Class Series 2 Programmer’s Manual
Control Panel Button Sequences
Three Button / Three LED Control Panel
Function Printer Mode Button Sequence
Pause Idle PAUSE
Feed / Clear Fault Idle FEED
Cancel Idle CANCEL
Soft Reset Idle PAUSE & CANCEL (or Long CANCEL)
Print Test Label Idle PAUSE & FEED
Print Configuration Label Idle FEED & CANCEL
Print Network Label Idle PAUSE, FEED, & CANCEL
Quick Calibration Idle Long FEED
Empty Calibration Idle Long PAUSE & FEED
Media Calibration * CANCEL
Reset Database to Configuration File * PAUSE & FEED
Menu / Setup * PAUSE
Reset firmware (but not Ethernet
parameters)
* PAUSE, FEED, & CANCEL
Reset firmware (and Ethernet
parameters)
* FEED & CANCEL
Hex Dump Mode Power-Up Hold FEED
Enter Boot Mode Power-Up Hold PAUSE & CANCEL
*Power “On” the printer then when the LEDs illuminate press and hold indicated the Button Sequence
until the LEDs extinguish.