Extended System-Level Command Functions
85
(SA) SOP Adjust – This command sets the start of print (SOP) location, relative to
the top of form. See <STX>O for command details. The EX2 accepts this command for
backward compatibility only, limited in range (28-228).
(SC) Scalable CacheThis command sets the number of 1K blocks allocated for
the scaleable font engine. Available memory dependent upon model; see Appendix
K.
(SE) SOP Emulation – This command enables the <STX>O and <STX>f print
positioning commands to allow backward compatibility with label formats designed
for other printers.
(SF) Save As Filename – This command, which may be sent separately or included
as the last command in an <STX>Kc command string, saves the effective printer
configuration to a file in Flash memory with a .dcm file extension.
(SG) Sensor Gain Value – This command sets the control of the voltage to the LED
emitter of the Media Sensor.